INFLUENCE OF PERMANENT MAGNET SIZE ON MAGNETIC PARAMETERS BASED ON MAGNETIC SYSTEM’S APPLICATION

Abstract: the workpresents the operating points of a cylindrical permanent magnet and the magnetic field parameters outside the magnetic pole depending on the application of the magnetic system (open, partially closed, and closed) at a constant volume. For the study, a cylindrical permanent magnet N35 with dimensions of 30x10[mmxmm] (base) was studied by changing the diameter and length while maintaining a constant volume. The effect of the PM dimensions on the main magnetic parameters was studied depending on the application options. The calculation results for open and closed magnetic systems, as well as the values of the magnetic field induction outside the magnet, are presented. The corresponding analyses and conclusions are made which can be useful for manufacturers and users of permanent magnets.

Keywords: permanent magnet, dimensions, magnetic system, magnetic parameters.

https://doi.org/10.24412/2712-8849-2025-384-466-473

Introduction. The purpose of using a permanent magnet (PM) is to ensure the needed magnitude of the magnetic field in an open-air location outside of the magnet (open magnetic system (Fig. 1a) or in point a of the working gap of the system with a magnetic wire (a semi-closed PM system) (Fig. 1b) or in a close magnetic system (Fig. 1c). a. b. c.Fig. 1. PM application optionsBased on the brand of the PM, they are produced in various designs and sizes. For example, the cylindrical PM of the N35 brand is produced with the following combinations of length ℓPM[mm} and diameter dPM[mm]: 30×10[mm×mm], 30×20[mm×mm], 35×5[mm×mm], 35×10[mm×mm], etc. [3].Such a choice of sizes by the PM manufacturer is determined mainly by technological processes, customer requirements, and some other circumstances. Therefore, depending on the magnetic system’s application, we analyse how justified these combinations of PM sizes depending on the magnetic parameters are.Proposed tasks.To study, at a constant volume of the magnetic field, the influence of the magnetic field dimensions on the main magnetic parameters depending on the application options of the magnetic system.The solution to the problem.For the study, a cylindrical PM of type N35 with dimensions of 30×10[mm×mm] (base) was examined, while the volume of VPM remained unchanged: VPM=7065mm3=const.The reference source for the N35 PM brand specifies the following magnetic parameters: coercive force by induction HcB=(836÷891)•103A/m, residual induction Br=(1.17÷1.22)T, maximum specific magnetic energy (BH)m=(263÷279)•103 J/m3 [4].For the study, the minimum values of the PM parameters were recorded: HcB=836•103A/m, Br=1.17T, (BH)m=263•103J/m3, since they satisfied the following conditions [2]HcBBr4(BHm(HcBBr,Br(2μ0 BHm,BHm(Br24μ0 ,BHmBr(HcB(4BHmBr.While maintaining the condition VPM=const, i.e. with constant mass, cost, and volumetric specific energy of the PM, the length ℓPM=(6÷14)mm and diameter dPM=(38,73÷25,35)mm changed within the specified limits.The magnetic parameters of the PM outside the magnetic system were calculated using the following mathematical expressions [1].Magnetic induction in neutral 00 section of the PM.B0=k0 −k0 2− 4μ0 (cmpHcBBr2(c,where k0 =(Br+μ0mpHcB), μ0 =4π10-7Hn/m.Magnetic field strength between the poles of the PMH0= B0μ0mp.Convexity coefficient of PM’s material(c=2 HcBBrBHm−HcBBrBHm .The permeability coefficient of the PM’s formmp=2,46dPMℓPM−1,32.Magnetic induction at the pole BN PMBN=(μ0H0+B0(ℓPM4ℓPM2+dPM2.The magnetic induction of scattering of the PMBσ=B0−BN.PM’s scattering coefficient by magnetic inductionkσ=B0BN.The values H0 and B0 determine the operating points A0, and the values HN and BN determine the operating points AN on the PM’s B(-H) characteristic (Fig. 2).After placing the PM in the magnetic system, the operating points A0 and AN of the PM shift in the return line due to the increase in the conductivity of the magnetic system.In the case of a closed magnetic system, H0=0 (magnetic losses in the magnetic circuit are not considered) and the operating points are located on the B axis, in positions A0´ and AN´, respectively (Fig. 2).In the case of a partially closed magnetic system, the operating points of the PM will occupy an intermediate position.In a closed magnetic system, the inductions corresponding to the operating points are determined as follows (magnetic losses in the magnetic circuit are neglected, and the magnetic conductivity of the leakage fluxes remains unchanged) [2].B0´(B0+H0(r, BN´(B0´−Bσ,where (r is the regression coefficient: (r=BrHcB(1−(c).The calculation data are given in Table 1.Table 1- Magnetic parameters of the PM according to different combinations of PM’s dimensions where VPM=const.The characteristic of the PM B(-H) and the magnetic energy Wi(Bi) in the plane of the coordinate axes were constructed using known expressions (Fig. 2):Bi=BrHcB−HiHcB−(cHi ,Wi=BiHi2.Fig. 2 shows the positions of the working points of the PM according to their dimensions: extreme values: A1- ℓPM=6mm, dPM=38,73mm, A2- ℓPM=14mm, dPM=25,35mm, and basic: A0- ℓPM=10mm, dPM=30mm.Due to the high density of conditional points, the figure does not show the positions of operating points A0´, A1´ and A2´, which occupy higher positions, respectively.Fig. 2. Characteristics and operating points of the PM B(-H) and W(B).The induction Ba of the magnetic field created at a point a, a distance x from the pole of the magnetic field in an open magnetic system (Fig. 1.a), was calculated by the following expression:Ba=(μ0H0+BN(ℓPM+x4(ℓPM+x(2+dPM2−x4x2+dPM2.The calculated data are presented in Table 2.Table 2. Values of magnetic field induction Ba at point a of an open magnetic system for different combinations of PM sizes where VPM=const.Research results.1. Open magnetic system. Having VPM=const, when increasing ℓPM, dPM decreases and the working points A0 and AN of the PM shift from left to right on the characteristic (Fig. 2), resulting in an increase in the values of induction B0 and BN. According to W, the working point is shifted to the maximum energy range. When comparing the values of the PM according to the extreme ℓPM=6mm and ℓPM=14mm, the following increase: B0 by 3,2, BN by 2,6, Bσ by 6,5, kσ by 1,2, W by 1,9 (Table 1).The magnetic field strength H0 between the poles of the PM decreases by about 1,7.The values of Ba induction increase by about 2,1 in the case of X=2mm when ℓPM=6÷14mm, and by about 1,5 in the case of X=8mm (Table 2).2. Closed magnetic system: In the case of ℓPM=6mm, the value of B0 increases by about 5,6, from 0,189T to 1,054T, and BN by 6,4, from 0,161T to 1,026T. In the case of ℓPM=14mm, B0 increases by 1,8, from 0,61T to 1,129T, and BN by 2,2, from 0,427T to 0,947T. In the case of ℓPM=10mm, B0 increases by 2,7, from 0,412T to 1,099T, and BN by 3,2, from 0,313T to 0,999T.3. Partially closed magnetic system with a magnetic wire. Depending on the size of the working air gap, the magnetic parameters of the working points of the PM will have intermediate values compared to open and closed magnetic systems.Conclusion1. In terms of all components of magnetic induction in an open magnetic system, increasing the length of the PM by decreasing the diameter, while keeping the volume unchanged, is effective.2. Due to the decrease in BNs induction in closed magnetic systems, using a PM with a reduced length and an increased diameter becomes preferable.3. When determining the size of the PM, the producing enterprises should pay attention to the data and conclusions presented in the work.Gratitude.The work was carried out in the basic scientific laboratory “Automation and Electromagnetic Systems”, funded by the Ministry of Education, Science, Culture and Sports of the Republic of Armenia.


Полная версия статьи PDF

Номер журнала «Вестник науки» № 3 (84) том 5


Ссылка для цитирования:

Hovhannisyan A.T. INFLUENCE OF PERMANENT MAGNET SIZE ON MAGNETIC PARAMETERS BASED ON MAGNETIC SYSTEM’S APPLICATION // Журнал «Вестник науки» от 28 марта 2025 г. № 3 (84) том 5. С. 466 - 473. 2025 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/22078 (дата обращения: 29.11.2026 г.)


Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/22078



Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com


Вестник науки © 2025.    16+




* В выпусках журнала могут упоминаться организации (Meta, Facebook, Instagram) в отношении которых судом принято вступившее в законную силу решение о ликвидации или запрете деятельности по основаниям, предусмотренным Федеральным законом от 25 июля 2002 года № 114-ФЗ «О противодействии экстремистской деятельности» (далее - Федеральный закон «О противодействии экстремистской деятельности»), или об организации, включенной в опубликованный единый федеральный список организаций, в том числе иностранных и международных организаций, признанных в соответствии с законодательством Российской Федерации террористическими, без указания на то, что соответствующее общественное объединение или иная организация ликвидированы или их деятельность запрещена.