DESIGN OPTIMIZATION OF HYBRID GEOTHERMAL-PV HEATING SYSTEMS FOR SEVERE CONTINENTAL CLIMATES
Abstract: air source heat pumps (ASHP) prove fundamentally inadequate for heating systems in Northern Kazakhstan, where winter design temperatures reach −35°C and the heating season extends 215 days annually. Under these conditions, ASHP coefficient of performance (COP) degrades to 1.0−1.2, rendering electrical heating more efficient and economically prohibitive. Ground source heat pump (GSHP) systems with deep vertical probes maintain consistent COP values of 3.2−4.5 throughout winter, exploiting stable soil temperatures at depth. This paper presents the engineering design rationale for a hybrid geothermal-photovoltaic system optimized for Astana, Kazakhstan. The system employs brine-to-water heat exchange at depths of 70 m, where ground temperature remains stable at +8°C regardless of atmospheric conditions. Bifacial photovoltaic arrays installed at 70° tilt maximize energy capture during winter months through ground albedo effects. Integrated performance analysis demonstrates that GSHP systems achieve seasonal coefficients of performance (SCOP) exceeding 4.2 throughout January, while bifacial PV systems generate 1.5× more annual energy than fixed horizontal configurations. The design methodology follows VDI 4640 standards and validated thermal response testing protocols. This engineering solution represents the only technically reliable approach for heating continuity in extreme continental climates where air temperature extremes exceed heat pump operating limits.
Keywords: GSHP, geothermal heating, photovoltaics, cold climate, borehole design, bifacial PV, COP, SCOP, thermal inertia, winter optimization.
1. Introduction. 1.1 Climatic Constraints of Northern Kazakhstan. Astana, located at 51.16°N latitude, experiences one of the worlds most extreme continental climates among major population centers. The climate is characterized by temperature extremes spanning 70°C annually, with particular severity during the heating season (October through April, 215 days total duration).Table 1.
Design Climate Parameters (per SN RK 2.04-01-2017).The severity of these conditions creates a fundamental engineering problem: standard heating technologies developed for temperate climates prove inadequate, and unconventional solutions become technically necessary.1.2 Why Air Source Heat Pumps Fail in Kazakhstan. Air source heat pumps represent the dominant heating technology in temperate Europe and Asia, where winter temperatures rarely extend below −20°C. The physics of ASHP operation, however, establishes hard performance limits in extreme cold.ASHP COP Degradation Mechanism:The coefficient of performance of an air source heat pump is fundamentally constrained by Carnot cycle thermodynamics:COP
Полная версия статьи PDF
Номер журнала «Вестник науки» № 12 (93) том 3
Ссылка для цитирования:
DESIGN OPTIMIZATION OF HYBRID GEOTHERMAL-PV HEATING SYSTEMS FOR SEVERE CONTINENTAL CLIMATES // Журнал «Вестник науки» от 21 декабря 2025 г. № 12 (93) том 3. С. 1518 - 1528. 2025 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/27673 (дата обращения: 29.11.2026 г.)
Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/27673
Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com