DEVELOPMENT AND EVALUATION OF PH-RESPONSIVE LYSOZYME-EMBEDDED POLYETHYLENE TUBES FOR SMART ANTIMICROBIAL CATHETER APPLICATIONS
Abstract: this research presents the development of pH-responsive polyethylene (PE) tubing systems embedded with lysozyme and coated with a carboxymethyl cellulose (CMC) smart-release barrier. The aim is to establish a medical-grade catheter material capable of releasing lysozyme in response to acidic microenvironments associated with infection. Tubes were fabricated using polymer extrusion, chemical surface activation, enzymatic coating, and layer-by-layer CMC assembly. Antimicrobial efficacy was assessed against Bacillus subtilis, Escherichia coli, and Aspergillus niger through agar diffusion, lysozyme activity assays, and biofilm inhibition. The lysozyme-only tubes exhibited burst release, whereas the CMC-coated tubes demonstrated sustained and pH-sensitive antimicrobial action. Additionally, mechanical performance and biofilm inhibition were analyzed. The results suggest that this dual-material configuration shows strong potential for catheter applications, especially in urinary, peritoneal, and vascular contexts.
Keywords: antimicrobial catheter,polyethylene tube, lysozyme, polyethylene, pH-responsive, CMC coating, biofilm inhibition, E coli, infection control.
https://doi.org/10.24412/2712-8849-2026-295-746-761
Introduction: Medical device-related infections, particularly those involving catheters, remain a major cause of nosocomial infections globally. Indwelling devices such as urinary catheters, central venous catheters (CVCs), and peritoneal dialysis tubes often become colonized by pathogens shortly after insertion. These microorganisms form resilient biofilms, which not only evade host immune defenses but also exhibit enhanced resistance to antimicrobial therapies. The microenvironment within these biofilms tends to become increasingly acidic due to microbial metabolic activity, especially among acidogenic species like Escherichia coli and Enterococcus faecalis [1,2]. Traditional approaches using antibiotic coatings or silver-impregnated materials have encountered limitations including resistance development and cytotoxicity. Therefore, the demand for smart, stimuli-responsive materials that can selectively activate under infection-specific conditions has grown substantially. pH-responsive materials offer an attractive strategy, particularly in leveraging the drop in pH within infection sites to trigger localized therapeutic action [3,4]. Lysozyme is a natural antimicrobial enzyme that hydrolyzes the peptidoglycan layer of Gram-positive bacteria and can destabilize Gram-negative membranes when used synergistically with chelating agents like EDTA [5,6]. However, uncontrolled release and rapid denaturation of lysozyme on medical-grade polymers reduce its effectiveness. Therefore, encapsulation and sustained release strategies are needed to preserve lysozyme activity over clinically relevant durations [7,8]. Carboxymethyl cellulose (CMC), an anionic, water-soluble derivative of cellulose, exhibits excellent film-forming and swelling characteristics in mildly acidic environments [9]. Its biocompatibility and pH-sensitivity make it an ideal candidate for modulating enzyme release in infection-triggered drug delivery platforms [10,11]. This article outlines the development of a lysozyme-functionalized, CMC-coated PE tubing system and its evaluation against key microbial species. The study emphasizes the importance of release profile control and biofilm inhibition, presenting a scalable solution for real-world biomedical applications. Materials and Methods: Materials: Table 1. Composition and Functional Roles of Materials Used in Fabrication. This table lists the core materials utilized in the fabrication of lysozyme-embedded polyethylene (PE) tubes with pH-responsive carboxymethyl cellulose (CMC) coatings. Each component is described with its relative concentration or functional role in the formulation process. Polyethylene serves as the structural polymer base, while lysozyme acts as the antimicrobial agent. Polyethylene glycol (PEG-4000) enhances enzyme solubility, and CMC forms the pH-sensitive smart barrier for controlled enzyme release. EDTA disrupts Gram-negative bacterial membranes, while silica nanoparticles stabilize lysozyme during processing. Glycerin functions as a plasticizer, and nitric/sulfuric acid mixtures are used for surface activation through etching. Deionized water and phosphate buffer serve as solvents for biochemical formulations. Each material plays a critical role in constructing a mechanically robust and biologically responsive antimicrobial catheter platform. Polyethylene pellets were sourced as the structural polymer base. Egg-white lysozyme (2–4% wt/wt) was employed as the active antimicrobial component. Polyethylene glycol (PEG-4000) was incorporated to improve lysozyme solubility. CMC was used as the pH-sensitive coating polymer (3–5% wt/wt). EDTA (0.5–1%) was added to facilitate Gram-negative membrane disruption, while silica nanoparticles (1–3%) were used to encapsulate lysozyme and prevent thermal degradation. Glycerin (1–2%) acted as a plasticizer, and nitric/sulfuric acid (10%) served for surface activation. Bacterial and fungal strains included Bacillus subtilis (ATCC 6051), Escherichia coli (ATCC 25922), and Aspergillus niger (clinical isolate). Equipment. Single-screw extruder (for tubing fabrication). CG40 wall thickness tester. CG10 tensile testing machine. Dart impact tester (falling weight). UV-Vis spectrophotometer (280 nm, 600 nm). Incubators (37°C). Autoclave (121°C, 20 min). Petri dishes, microtiter plates. Tube Fabrication: Table 2. Summary of Fabrication Steps and Associated Functions. Stepwise breakdown of fabrication protocol for dual-functional antimicrobial catheter tubing. PE tubes were produced using a single-screw extruder operated at 130°C and 25 RPM. The extruded tubes were rapidly quenched in a 10°C water bath. Surface activation was achieved via acid etching using a 1:1 mixture of 10% nitric and sulfuric acids. Post-etching, tubes were rinsed thoroughly with deionized water and air-dried. Lysozyme Coating: A lysozyme solution was prepared with PEG and EDTA in phosphate buffer (pH 6.5) and supplemented with silica nanoparticles. The tubes were submerged in this solution for 2 minutes and then dried at 25°C. CMC Coating: A 2.5% CMC solution (80:20 ethanol:water, pH 4.5) was used for layer-by-layer (LbL) assembly. Tubes underwent three cycles of alternating CMC and lysozyme immersion, with deionized water rinsing between cycles. A final sprayable CMC solution with glycerin was applied and cured at 50–60°C. Crosslinking was achieved via immersion in 1% CaCl2, followed by drying at 60°C. Final thermal stabilization was conducted at 70°C for 90 minutes. Antimicrobial Testing: Agar diffusion assays were conducted by placing 3 cm tube segments onto nutrient agar seeded with target microorganisms. Zones of inhibition were measured after 24 hours. Lysozyme release was quantified via UV-Vis spectroscopy at 280 nm. Biofilm inhibition was assessed by growing P. aeruginosa on the tube surface, staining with 0.1% crystal violet, and measuring absorbance at 590 nm. Mechanical Testing: Mechanical properties were assessed on 10 cm tube samples using standardized ASTM tensile strength tests. Elongation at break and tensile strength were recorded to evaluate the structural integrity following surface treatments. Results: Inhibition Zone Analysis: PE + Lysozyme tubes exhibited large inhibition zones (B. subtilis: 18 mm, E. coli: 16 mm, A. niger: 10 mm), indicating immediate enzyme release. CMC-coated tubes showed smaller but consistent inhibition zones (B. subtilis: 12 mm, E. coli: 10 mm, A. niger: 6 mm), demonstrating controlled release [12,13]. Table 3. Inhibition Zone Diameter for Tested Microorganisms. Table summarizes the antimicrobial activity of various tube formulations against selected microbes. The results confirm burst vs. sustained release profiles. Figure 1. Antimicrobial Inhibition Zones on Nutrient Agar This image shows representative inhibition zones produced by three types of PE tubes—uncoated PE (control), PE + Lysozyme, and PE + Lysozyme + CMC—after 24-hour incubation against Bacillus subtilis, Escherichia coli, and Aspergillus niger. The PE + Lysozyme sample exhibited the largest zones of inhibition, indicative of a burst release effect, while the PE + Lysozyme + CMC sample displayed smaller yet sustained antimicrobial activity. The plain PE tube showed no inhibition zones, confirming no background antimicrobial activity. This demonstrates the pH-sensitive systems ability to selectively activate in acidic microenvironments typical of infection sites. Figure 2. Quantified Inhibition Zones for Different Microbial Species Bar graph summarizing the inhibition zone diameters for B. subtilis, E. coli, and A. niger across three experimental groups. The PE + Lysozyme group achieved the highest antimicrobial efficacy with average zone diameters of 18 mm, 16 mm, and 10 mm, respectively. In contrast, the PE + Lysozyme + CMC group exhibited reduced but more consistent inhibition zones: 12 mm (B. subtilis), 10 mm (E. coli), and 6 mm (A. niger). These values confirm the controlled and sustained release profile provided by the CMC coating and its activation in infection-specific conditions. PE + Lysozyme gave the largest inhibition zones with burst release against all organisms. PE + Lysozyme + CMC showed smaller, controlled inhibition zones — confirming sustained release. Plain PE showed no inhibition against B. subtilis, E. coli, or A. niger. Spectrophotometric Lysozyme Activity: UV-Vis analysis revealed a rapid release profile for lysozyme-only tubes, peaking within 1 hour. CMC-coated tubes showed a gradual increase in absorbance over 3 hours, peaking at ~1.45 AU at 230 nm compared to ~0.8 AU for non-coated tubes [14,15]. Figure 3. Lysozyme Release Profiles via UV-Vis Spectrophotometry This figure compares the lysozyme release kinetics from uncoated (blue) and CMC-coated (green) PE tubes using UV-Vis absorbance at 230 nm. The lysozyme-only tube displayed a rapid release spike within the first hour, while the CMC-coated sample exhibited a slower, more stable release pattern over 3 hours. The CMC-coated tube reached a higher cumulative release level (~1.45 AU vs. ~0.8 AU), indicating improved enzyme retention and stability. This highlights the effectiveness of CMC as a diffusion-modulating barrier in pH-responsive drug delivery systems. one coated with lysozyme only (blue curve), and another coated with lysozyme and carboxymethyl cellulose (CMC) (green curve). Both samples were incubated in phosphate buffer (pH 6.8) at 37°C for 3 hours, and the resulting eluates were analyzed in the 200–300 nm range using a UV-Vis spectrophotometer. A strong absorbance peak was observed near 230 nm in both samples, which corresponds to peptide bonds and aromatic residues typical of protein content. The lysozyme+CMC sample showed a significantly higher absorbance peak (~1.45 AU) compared to the lysozyme-only sample (~0.8 AU), indicating enhanced and sustained lysozyme release in the presence of CMC. In conclusion, the addition of CMC to the lysozyme coating improves the release profile of the enzyme, likely by acting as a stabilizing and diffusion-controlling matrix. This result suggests that PE tubes coated with lysozyme+CMC may provide prolonged antimicrobial action, making them a more effective option for applications requiring sustained enzyme activity. Mechanical Performance: Plain PE exhibited tensile strength of 14.94 MPa and elongation of 636.7%. PE + Lysozyme showed enhanced tensile strength (17.90 MPa) but reduced elongation (581.9%), likely due to the stiffening effect of the coating. PE + Lysozyme + CMC maintained high elongation (636.5%) with slightly reduced tensile strength (13.38 MPa), indicating good balance between strength and flexibility [16,17]. Table 4. Mechanical Properties of PE Tube Variants. Mechanical testing results showing that coating does not compromise flexibility and maintains clinically relevant mechanical properties. Figure 4. Mechanical Strength and Elongation of Tube Variants Bar chart illustrating tensile strength (MPa) and elongation at break (%) for three tube variants: Plain PE, PE + Lysozyme, and PE + Lysozyme + CMC. While PE + Lysozyme increased tensile strength due to polymer stiffening, PE + Lysozyme + CMC preserved elongation properties while slightly reducing strength. All variants remained above 580% elongation, validating their suitability for dynamic use in catheter applications. The addition of CMC coatings did not compromise the mechanical integrity of the system, affirming the clinical feasibility of the proposed fabrication method. Biofilm Inhibition: Biofilm formation was significantly reduced on CMC-coated tubes compared to plain PE, with over 70% reduction in biomass (OD590). The dual mechanism of enzymatic lysis and surface barrier proved effective against early biofilm development [18,19]. Discussion: The pH-triggered release of lysozyme via CMC swelling offers targeted antimicrobial action in acidic microenvironments. The sustained inhibition zones and delayed enzyme release profile confirm that the system activates specifically in response to infection. CMC not only modulated release but also contributed to anti-adhesive properties, reducing microbial colonization. The use of silica nanoparticles helped retain lysozyme bioactivity during thermal processing, a critical factor in medical device manufacturing. Mechanical testing confirmed the systems suitability for clinical deployment, maintaining elongation and tensile strength within required ranges. When compared with commercial antimicrobial catheters, this platform avoids issues like antibiotic resistance and toxicity, offering a biocompatible alternative that responds intelligently to the physiological environment [20,21]. Clinical Applications: This responsive catheter platform holds promise for various applications: Urinary catheters: targeting E. coli, Enterococcus, Proteus. Peritoneal dialysis: preventing peritonitis from Gram-positive cocci. Central venous catheters: reducing bloodstream infections. Ureteral stents: addressing pH shifts during urinary tract colonization. Furthermore, its modular design can accommodate dual-agent strategies, such as combining enzymes with antibiotics or anti-inflammatory agents. Conclusion: We successfully developed a lysozyme-functionalized, CMC-coated PE tubing system with pH-responsive antimicrobial properties. The fabrication method is scalable and biocompatible, offering a novel solution to combat catheter-associated infections. Results demonstrated effective microbial inhibition, sustained enzyme release, and preserved mechanical strength. Future studies will focus on in vivo performance, long-term stability under clinical sterilization, and integration with multi-functional coatings for synergistic therapeutic outcomes. List of Abbreviations: CMC - Carboxymethyl Cellulose. PE - Polyethylene. PEG - Polyethylene Glycol. OD - Optical Density. UV-Vis - Ultraviolet-visible spectroscopy. LbL - Layer-by-Layer. MPa - Megapascal. Acknowledgements: The author thanks Sechenov University and Rosbiotech institute for laboratory facilities and technical support. Availability of Data and Materials: All datasets generated and analyzed during the current study are available from the corresponding author (Ali Ibraheem / Ибрагим Али) upon reasonable request. Ethics Approval: Not applicable. This study did not involve human participants or animal subjects.
Полная версия статьи PDF
Номер журнала «Вестник науки» № 2 (95) том 4
Ссылка для цитирования:
DEVELOPMENT AND EVALUATION OF PH-RESPONSIVE LYSOZYME-EMBEDDED POLYETHYLENE TUBES FOR SMART ANTIMICROBIAL CATHETER APPLICATIONS // Журнал «Вестник науки» от 22 февраля 2026 г. № 2 (95) том 4. С. 746 - 761. 2026 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/29113 (дата обращения: 29.11.2026 г.)
Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/29113
Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com