PREDICTIVE ANALYSIS OF ACCIDENTS AT RENEWABLE ENERGY FACILITIES
Abstract: this paper presents an approach to predictive analysis of emergency conditions at renewable energy facilities based on integrated processing of power quality data and meteorological parameters. The proposed system collects and analyzes historical data obtained from the SATEC PM180 power quality analyzer and integrates meteorological information from local weather stations as well as external sources, including open APIs (e.g., NASA).The study focuses on the development of a software architecture implemented in Python, which provides automated data acquisition, storage, and processing, as well as the formation of predictive models. Based on the identified relationships between weather conditions and electrical network parameters, the system is capable of forecasting the probability of emergency events and providing early warnings to operators.The results demonstrate that the use of predictive analytics can improve the reliability of renewable energy facilities, reduce the risk of emergency outages, and optimize operational processes. The proposed approach can be applied in monitoring and control systems for power facilities in the context of increasing penetration of renewable energy sources.
Keywords: predictive analytics, renewable energy, power quality, fault prediction, meteorological data, SATEC PM180, machine learning, SCADA systems, data acquisition, energy monitoring, Python systems, anomaly detection.
Object of study: a typical RES facility and measurement points. The object of study is a typical renewable energy facility in one of three common configurations: a solar power plant (PV), a wind power plant (WPP), or a hybrid site (PV+wind and/or PV+storage). For predictive fault analysis, the site is treated as a system composed of: generation subsystems (PV inverters, wind turbines and converters, for hybrids, also battery storage and PCS), power evacuation equipment (step-up transformer, switchgear, feeders), the point of common coupling (PCC / grid interconnection point), measurement and weather monitoring subsystems (power quality analyzer, weather station), event logs (SCADA/automation system logs, protection relay/switching logs, inverter/turbine logs). Measurement points that are most useful for predicting faults typically include: (1) PCC or the outgoing feeder on the MV/LV side, where voltage/frequency deviations and power quality (PQ) events are captured, (2) transformer sides (LV/MV) to detect overload and unbalance, and (3) aggregated operational indicators across inverter strings or turbines (power, trips, alarm states).
In this mini-study, the main electrical measurement backbone is the PM180 device installed at a key point (most often at the PCC or an outgoing feeder). Data sources and characteristics. Electrical measurements: PM180. The primary electrical measurement instrument is the PM180 manufactured by SATEC.
According to the official PM180 datasheet, the device supports waveform/event recording and fast trend logging (fast data recorders), which are essential for linking precursors to later trips or PQ-related disconnections (official SATEC PM180 documentation). Parameters included in the study (minimum practical set): RMS and basic grid operating quantities: voltages/currents, frequency, power and related aggregates, for fault prediction, frequency, unbalance, and abrupt changes in current/voltage are especially informative (official SATEC PM180 documentation). Distortion / harmonics: THD and (if available in the exposed register set) harmonic components. The PM180 operation manual describes harmonic analysis based on an FFT computed over 10 cycles (for 50 Hz) or 12 cycles (for 60 Hz) using 256 samples per cycle, providing spectral components up to the 63rd harmonic (official SATEC PM180 documentation).
Power quality events: sags/swells and other PQ events (at least their occurrence and counts per time window), as well as transient events when waveforms are retrieved. Waveforms: the PM180 datasheet indicates waveform recording at 32/64/128/256 samples per cycle and the ability to retain pre-fault cycles (official SATEC PM180 documentation). Fast data recorders: the datasheet describes 16 fast data recorders (up to 16 parameters per recorder) with intervals ranging from ½-cycle RMS to 2-hour RMS envelopes (official SATEC PM180 documentation). Data format and integration.
When polling via Modbus, values are delivered as 16-bit and 32-bit registers, some counters use a 32-bit modulo-10000 format. The Modbus reference documentation also specifies «low-order word first» for 32-bit values and alignment requirements (official SATEC PM180 documentation). Sampling / update rate. Internal measurement windows and logging intervals are partially documented (e.g., fast RMS windows and logging timers).
However, the «recommended external polling rate over Modbus for predictive analytics» is not specified. Reasonable pilot defaults are: 1–5 seconds for «dashboard-grade» RMS/THD/power/frequency (stable connectivity), 0.5–1 second for higher operational responsiveness (if the field network and the device can sustain it), waveform retrieval and detailed event extraction «by event / by schedule» rather than continuous high-frequency polling, because the device already supports event-driven recording and dedicated waveform/recorder functions (official SATEC PM180 documentation). On-site weather station. The weather station is treated as a second mandatory data stream because fault occurrence at RES sites frequently correlates with wind gusts, precipitation, humidity, and temperature extremes (via overheating, icing, soiling, storm curtailments, etc.).
Typical parameters included in the study are: air temperature, wind speed/direction (and gusts), relative humidity, atmospheric pressure, and precipitation (NOAA weather observations / NOAA CDO docs as concept sources). Measurement/reporting frequency for the specific weather station model is not specified. Reasonable pilot defaults are: «raw» wind at 1–2 seconds (or faster if supported), then aggregated to reporting windows, reporting aggregates at 1 minute (mean/max gust wind, precipitation increments, average T/RH/pressure), if communications are constrained: 5-minute reporting as a compromise, with reduced sensitivity to short gusts. External sources: NASA POWER and NOAA.
External sources are used to improve completeness and context, especially when the on-site sensor set is incomplete and to enrich features with radiation/meteorological background. NASA POWER. The NASA POWER temporal APIs (hourly/daily) provide analysis-ready time series for solar and meteorological parameters and support standard output formats used in Python pipelines. For the Hourly API, documentation explicitly notes that precipitation is expressed in mm/hour (NASA POWER API docs).
Integration in Python can be done via simple HTTP requests (requests) and CSV/JSON ingestion (pandas), with UTC normalization and time-based joins. NOAA CDO and NWS. For historical observations and cross-validation, NOAA Climate Data Online (CDO) Web Services v2 are used, documentation specifies the need for an access token and request limits (NOAA CDO docs). For operational forecasts/alerts (where NWS coverage applies), the NOAA/NWS API provides forecasts, warnings, and observations, using JSON-LD and a cache-friendly design (NOAA NWS docs).
The Alerts service guidance recommends not polling more frequently than once every 30 seconds due to rate limiting (NOAA NWS docs). In Python, these sources are integrated via requests (JSON) and cached fetch schedules to respect quotas. Methods: data acquisition, processing, and modeling. The methodology is designed to be reproducible and directly transferable into a pilot system.
Data acquisition. Two connector classes are used: on-site devices (PM180) via Modbus, implemented with pymodbus, external APIs (NASA POWER, NOAA) via requests and/or pandas. Practical value for the power supply system. For a power supply system (grid operator, dispatching center, and asset owner), deploying predictive analytics at renewable energy sites—PV plants, wind power plants (WPP), and hybrid configurations—creates measurable benefits across operations, economics, reliability, safety, compliance, and asset life cycle.
Operational benefits. The most immediate gain is fewer sudden disconnections (trips) and faster recovery when events still occur. Early risk warnings allow dispatchers and O&M teams to prepare corrective actions (e.g., operational setpoint adjustments, crew readiness, spare parts staging), reducing the «surprise factor» that typically drives longer outages. High-fidelity PQ event logs and waveforms also shorten troubleshooting because the incident can be diagnosed from objective measurements rather than «symptoms» seen in low-rate SCADA summaries (official SATEC PM180 documentation).
Economic benefits. Reduced unplanned downtime increases delivered energy and lowers penalties from non-availability or contracted performance breaches. Maintenance becomes more targeted: instead of periodic or purely reactive interventions, crews can prioritize inspections where risk is rising, reducing unnecessary truck rolls and overtime. In RES predictive maintenance literature—especially for wind—this shift from reactive to predictive O&M is a central value proposition, but it depends heavily on data quality and the ability to detect early indicators with sufficient lead time (recent RES predictive maintenance literature).
Reliability and grid stability. Predictive warnings help avoid clustered or cascading RES trips during stressed grid or weather conditions—events that can force increased reserve activation and additional curtailment. When the system forecasts elevated probability of disconnection in the next 1–6 hours, dispatchers can proactively re-balance, pre-position reserves, and adjust constraints rather than reacting after multiple inverters or turbines drop. This directly supports frequency stability and reduces the operational burden of uncertainty-driven reserve margins (recent literature on RES grid integration and PQ).
Safety and compliance. PQ measurements compliant with established PQ practices (e.g., Class A-grade measurements in the sense used by modern PQ analyzers) provide credible evidence for incident investigations and internal/external reporting. This reduces disputes around «who caused the event» and supports structured post-mortems that feed back into better settings, protection coordination, and maintenance plans (official SATEC PM180 documentation, relevant PQ compliance literature). Asset life-cycle impacts.
By detecting «pre-failure» signatures—rising THD, increasing event frequency, repeated sags/swells, abnormal unbalance trends, or weather-driven thermal stress—the system can trigger earlier inspections and corrective actions that prevent accelerated degradation, extending component life and stabilizing life-cycle costs (recent RES PdM literature).
Полная версия статьи PDF
Номер журнала «Вестник науки» № 4 (97) том 2
Ссылка для цитирования: