ULTRASONIC DIAGNOSTICS OF PARTIAL DISCHARGES IN ELECTRICAL MACHINES UNDER OPERATING CONDITIONS
Abstract: the article considers the use of ultrasonic techniques for detecting partial discharge activity in electrical machines during normal service operation. Since partial discharges are closely associated with the early stages of insulation deterioration, their identification can provide valuable information about developing defects before they lead to severe damage. The study outlines the mechanism of ultrasonic wave generation caused by discharge events, describes the basic principles of signal acquisition, and discusses the diagnostic importance of the recorded acoustic response. Special attention is given to advanced monitoring concepts based on digital analysis of measured signals and the use of several sensors positioned at different locations, which increases the confidence of defect recognition and improves assessment quality.
Keywords: electrical machines, insulation diagnostics, partial discharge detection, ultrasonic monitoring, condition assessment, acoustic signal analysis.
Introduction.Modern industrial economies rely heavily on the uninterrupted functioning of electric power generation, transmission, and distribution networks, as these systems form the basis for technological progress and economic stability. The dependable performance of such networks is determined not only by the design quality of their infrastructure and equipment, but also by the effectiveness of maintenance practices aimed at evaluating the condition of key assets. In this regard, high-voltage rotating electrical machines represent a particularly important category of equipment, since their service life and reliability are significantly affected by the combined action of electrical, thermal, and mechanical stresses during operation [1-3]. Maintaining the safety, efficiency, and durability of rotating machines requires the use of advanced diagnostic methods capable of identifying incipient defects before they develop into serious failures.
Conventional diagnostic procedures have often been based on intrusive inspections that require the machine to be taken out of service, which negatively affects availability and leads to additional maintenance expenses. As a result, condition assessment performed while the equipment remains in normal operation, usually referred to as online monitoring, has become an essential component of predictive and preventive maintenance strategies. Among modern online diagnostic techniques, partial discharge monitoring is considered one of the most valuable tools for evaluating insulation condition. Partial discharge phenomena are frequently associated with the early stages of insulation deterioration, which means that their detection can provide advance warning of developing faults.
This enables maintenance personnel to take corrective actions before severe damage or unexpected outages occur. Another important advantage of this method is that it allows the insulation system to be assessed without interrupting the operating process [4-7]. The overall effectiveness of partial discharge diagnostics is largely determined by the characteristics of the sensing devices employed, particularly their sensitivity, noise immunity, and measurement accuracy. A variety of sensor technologies are currently used for PD detection, such as high-voltage coupling capacitors, Rogowski coils, transient earth voltage sensors, acoustic sensors, radio-frequency sensors, and radio-frequency current transformers.
The choice of the most appropriate sensor depends on several factors, including the equipment under investigation, the surrounding measurement environment, the expected features of the discharge signals, and the specific diagnostic purpose of the monitoring system [8-10]. Ⅰ. Partial discharges as an indicator of insulation defects. The operational dependability of electrical machines is closely associated with the health of their winding insulation. Under service conditions, insulating materials are continuously subjected to a combination of electrical, thermal, and mechanical influences.
Over time, these stresses contribute to the formation of small imperfections, including internal voids, cracks, layer separation, and localized moisture ingress. Such weakened areas often become the sites where partial discharges originate. Partial discharge can be defined as a localized electrical event that takes place in only a restricted portion of the insulation system. While this phenomenon does not usually result in immediate breakdown of the machine, its repeated action accelerates the deterioration of dielectric material, weakens the insulation structure, and increases the probability of more serious defects developing.
Therefore, partial discharge is considered a highly valuable diagnostic sign for identifying early-stage insulation degradation before a major and clearly observable failure occurs [11-14]. Ⅱ. The essence of the ultrasonic diagnostic method. The development of partial discharge is associated not only with the appearance of an electrical pulse, but also with the generation of an acoustic signal. During the localized release of energy, ultrasonic vibrations are produced and then travel through the insulation, machine components, and housing structure.
By detecting these ultrasonic waves, it is possible to determine the presence of discharge processes within the equipment. In practical applications, ultrasonic diagnostics can be performed using either contact or non-contact techniques. Contact methods involve placing sensors directly on the external surface of the machine, whereas non-contact methods are based on capturing ultrasonic waves transmitted through air. The contact approach generally provides more stable measurement results, while the non-contact approach is often preferred for rapid inspections and easier application.
For both methods, it is important to consider that the measured signal may be weakened and altered as it propagates through the complex internal and external structure of the machine. III. Advantages, limitations, and elements of novelty. A major benefit of ultrasonic diagnostics is that it enables the condition of equipment to be evaluated while the machine remains in service.
This is particularly valuable at industrial sites, where shutdowns are often associated with production interruptions and financial losses. Another practical advantage of this technique is that it does not require direct electrical connection to high-voltage circuits and is therefore well suited for fast. operational assessment. At the same time, the diagnostic capability of the method is influenced by several factors, including background noise, the placement of sensors, and the path along which the acoustic wave travels. For this reason, effective modern diagnostics should not be limited to simple signal detection, but should also include digital processing of the recorded data, comparison of measurements obtained at different locations, and evaluation of signal parameter trends over time (figure 2).
Figure 2. Generalized digital workflow for ultrasonic monitoring of partial discharges. One of the most promising developments in this field is the application of multi-channel monitoring systems, where several sensors are installed in different parts of the machine. Such an arrangement improves the ability to locate defect sources and enhances the overall reliability of the diagnostic results.
Further improvement can be achieved by integrating ultrasonic monitoring with other diagnostic techniques, allowing a more comprehensive evaluation of insulation condition. The most important diagnostic characteristics for practical application are summarized in Table 1. Representative time-domain and frequency-domain signal plots relevant to ultrasonic partial discharge diagnostics are presented in Figure 3. These illustrative curves highlight three features commonly used in practical interpretation: the impulsive waveform shape, the damped oscillatory response after filtering, and the dominant spectral components within the ultrasonic band.
Table 1. Key diagnostic characteristics of the ultrasonic method. Figure 3. Representative illustrative signal plots used in ultrasonic partial discharge diagnostics: (a) impulsive time-domain waveform, (b) damped oscillatory response, and (c) frequency spectrum of the detected ultrasonic signal.
Conclusion. Ultrasonic partial discharge diagnostics is widely regarded as a valuable method for evaluating the insulation condition of electrical machines during normal operation. Its main practical benefit is the ability to reveal developing hidden defects at an early stage without the need to stop the machine. Although the method has certain constraints, it continues to offer strong potential, particularly when combined with digital signal analysis, measurements from multiple locations, and a comprehensive diagnostic strategy.
For this reason, ultrasonic diagnostics represents an important area in the advancement of modern condition monitoring technologies for electrical machines.
Полная версия статьи PDF
Номер журнала «Вестник науки» № 4 (97) том 4
Ссылка для цитирования:
ULTRASONIC DIAGNOSTICS OF PARTIAL DISCHARGES IN ELECTRICAL MACHINES UNDER OPERATING CONDITIONS // Журнал «Вестник науки» от 26 апреля 2026 г. № 4 (97) том 4. С. 1285 - 1292. 2026 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/30031 (дата обращения: 29.11.2026 г.)
Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/30031
Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com