ANALYSIS OF RELIABILITY AND MODERN DIAGNOSTIC METHODS OF HIGH-VOLTAGE ASYNCHRONOUS MOTORS

Abstract: high-voltage induction motors are widely used in industrial power systems due to their high efficiency, operational reliability, and ability to operate under heavy load conditions. However, failures related to stator insulation degradation, bearing wear, rotor defects, and electromagnetic asymmetry may lead to serious operational and economic losses. This paper presents an analysis of the reliability characteristics and modern diagnostic methods of high-voltage induction motors. Reliability indicators such as MTBF, MTTR, and Weibull distribution parameters are evaluated to assess the failure behavior of electrical machines. In addition, the effectiveness of Condition-Based Monitoring systems for early fault detection and reduction of unplanned downtime is investigated.

Keywords: high-voltage induction motor, diagnostics, reliability, MCSA, partial discharge, vibration analysis, artificial intelligence, condition-based monitoring.

The operational reliability of high-voltage (HV) induction motors is one of the key requirements for ensuring uninterrupted production processes in heavy industrial sectors such as petrochemical processing, underground mining, and offshore energy production. Due to their operation under high-voltage conditions, these motors are simultaneously exposed to severe electrical stresses, explosive environments, and aggressive climatic conditions associated with corrosion. Such complex operating conditions accelerate physical and chemical degradation processes within the structural components of the motor. In particular, insulation deterioration, corrosion of metallic parts, and mechanical wear significantly affect the technical condition and service life of the equipment.

The classification of hazardous areas for gas and vapor environments includes Zone 0, Zone 1, and Zone 2, while combustible dust environments are classified as Zone 20, Zone 21, and Zone 22. Zone 0 and Zone 20 represent areas where explosive atmospheres are continuously or frequently present, whereas Zone 1 and Zone 21 correspond to areas where such conditions may occur during normal operation. Zone 2 and Zone 22 describe areas where explosive atmospheres are unlikely to occur and exist only for short periods. Within this classification system, the chemical properties and ignition capability of flammable substances determine the required level of explosion protection.

Figure 1 presents a generalized classification of hazardous areas and the corresponding explosion protection types used for electrical equipment selection. Figure 1. Selection Scheme of Protection Types for High-Voltage Motors in Hazardous Areas. PD signals are typically measured using coupling capacitors (CC) connected to motor terminals or high-frequency current transformers (HFCT) installed on grounding lines.

These measurements enable the early detection of local insulation defects. Phase-Resolved Partial Discharge (PRPD) analysis is used to identify discharge distribution characteristics and determine fault sources such as internal voids, surface contamination, and insulation irregularities. Measurement procedures are generally performed in accordance with IEEE Std 1434-2000 and IEC 60270 standards. To reduce the influence of electromagnetic interference (EMI) in industrial environments, digital signal processing methods such as Discrete Wavelet Transform (DWT) and Second-Generation Wavelet Transform (SGWT) are widely applied.

In recent years, multimodal deep learning models, particularly CNN–LSTM architectures, have demonstrated high diagnostic accuracy in noisy environments. In addition to insulation monitoring, electromagnetic and mechanical faults in high-voltage induction motors can be diagnosed using Motor Current Signature Analysis (MCSA). This method analyzes characteristic frequency components in stator current signals and allows fault detection without additional sensors. MCSA is especially effective in identifying rotor bar failures and magnetic asymmetries through the analysis of sideband frequency components in the current spectrum. ???=??1±2?. here: ?? — supply frequency, ? — slip coefficient, ??? — sideband frequencies associated with rotor faults.

An increase in the amplitude of these sideband frequency components indicates structural defects in the rotor cage and enables early fault detection. Therefore, MCSA is considered an effective diagnostic tool for evaluating the internal electromagnetic condition of induction motors, complementing conventional vibration analysis. Here, ??? represents the sideband frequency components, ?? denotes the fundamental supply frequency, and ? is the motor slip coefficient. Figure 2. presents the stator current spectrum obtained using the Fast Fourier Transform (FFT) technique.

Under slip conditions of s=0.02 characteristic sideband frequency components associated with broken rotor bar faults are observed at frequencies ??(1−2?) and ??(1+2?), corresponding approximately to 48 Hz and 52 Hz, respectively. Figure 2. MCSA FFT spectrum of broken rotor bar fault and characteristic sideband frequencies (48 Hz and 52 Hz) at slip ( s = 0.02 ). An increase in the amplitude of these components serves as a diagnostic indicator of structural defects in the rotor cage.

Infrared thermography is effective for detecting abnormal temperature distributions, while vibration analysis provides accurate identification of bearing and rotor-related faults through characteristic frequency components. However, each method has individual limitations when applied separately. To improve diagnostic accuracy, modern monitoring systems use feature-level fusion techniques, where data from multiple sensors are jointly processed and analyzed. Methods such as Principal Component Analysis (PCA) and Kalman filtering are applied for noise reduction and data optimization.

In addition, Fuzzy Logic, Bayesian approaches, ANFIS, and Support Vector Machines (SVM) are widely used to reduce false alarms and enhance fault classification performance. The operational reliability of high-voltage (HV) induction motors is strongly influenced by complex fault mechanisms caused by interacting thermal, electrical, environmental, and mechanical stresses. Among motor components, the stator insulation system is considered one of the most critical elements affecting overall reliability. The main degradation factors are commonly classified according to the TEAM (Thermal, Electrical, Ambient, Mechanical) stress model.

Thermal stresses accelerate insulation aging, leading to embrittlement of epoxy-based materials and weakening of adhesion between conductors and insulation layers. In industrial practice, the widely used «10°C rule» states that every 10°C increase above the rated insulation temperature approximately halves insulation lifetime. Electrical stresses, particularly Partial Discharge (PD) activity and high-frequency voltage pulses generated by Variable Frequency Drives (VFDs), significantly accelerate dielectric degradation processes. Insulation assessment and monitoring procedures are generally performed according to IEEE Std 43, IEEE Std 1434, and IEC 60034-27 standards.

Another critical fault mechanism in VFD-fed HV induction motors is electrical bearing damage. This phenomenon occurs when shaft voltage exceeds the dielectric strength of the bearing lubricant film, causing repetitive electrical discharges inside the bearing. As a result, microscopic craters and surface erosion develop, eventually leading to bearing failure. A major source of this problem is Common-Mode Voltage (CMV) generated by variable frequency converters. ???=??+??+??3.??, ??, ?? — phase voltages, ??? — common-mode voltage.Recent studies show that conventional threshold-based approaches are often insufficient for accurate bearing fault detection in high-voltage induction motors.

Instead, machine learning and deep learning methods provide improved diagnostic sensitivity through advanced analysis of signal characteristics. The integration of multiple diagnostic techniques enables early fault detection, typically from several weeks up to five months before failure. Research indicates that such approaches can identify nearly 70% of faults at an early stage while significantly reducing false-positive rates compared to single-method diagnostics. Deep learning models have demonstrated clear advantages over traditional diagnostic systems in terms of accuracy and reliability.

For example, the ResNet-18 convolutional neural network can detect early-stage stator winding faults with an accuracy of approximately 97.8–99%, while reducing the false-positive rate to about 0.66%. In contrast, conventional threshold-based systems may produce false-positive rates of up to 25% (fiqure 3). Fiqure 3. Comparison of the False Positive Rate between the conventional threshold-based diaqnostic method and the ResNet-18-based deep learning model.

Long Short-Term Memory (LSTM) networks have also shown high effectiveness in diagnosing electrical faults, achieving diagnostic accuracies between 95.33% and 100%. These models are particularly suitable for analyzing time-series signals and tracking insulation resistance degradation trends. Practical implementation of AI models in industrial environments is often affected by the domain shift problem, caused by statistical differences between laboratory and real operating conditions. The application of Condition-Based Monitoring (CBM) and predictive maintenance approaches significantly improves the operational continuity and maintenance efficiency of high-voltage induction motors.

These methods enable early fault detection and reduce the risk of unplanned downtime.


Полная версия статьи PDF

Номер журнала «Вестник науки» № 5 (98) том 4


Ссылка для цитирования:

Gadirzade N.M. ANALYSIS OF RELIABILITY AND MODERN DIAGNOSTIC METHODS OF HIGH-VOLTAGE ASYNCHRONOUS MOTORS // Журнал «Вестник науки» от 24 мая 2026 г. № 5 (98) том 4. С. 2841 - 2848. 2026 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/30971 (дата обращения: 29.11.2026 г.)


Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/30971



Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com


Вестник науки © 2026.    16+




* В выпусках журнала могут упоминаться организации (Meta, Facebook, Instagram) в отношении которых судом принято вступившее в законную силу решение о ликвидации или запрете деятельности по основаниям, предусмотренным Федеральным законом от 25 июля 2002 года № 114-ФЗ «О противодействии экстремистской деятельности» (далее - Федеральный закон «О противодействии экстремистской деятельности»), или об организации, включенной в опубликованный единый федеральный список организаций, в том числе иностранных и международных организаций, признанных в соответствии с законодательством Российской Федерации террористическими, без указания на то, что соответствующее общественное объединение или иная организация ликвидированы или их деятельность запрещена.