A VARIANT OF SIMULATION MODELING FOR A TECHNOLOGICAL OBJECT IN SIMULINK/SIMSCAPE

Abstract: this research paper examines methods for developing simulation models when studying the thermal conditions of buildings and technological objects.

Keywords: individual heating substation, Simscape, dynamic modeling, shell-and-tube heat exchanger, heating systems, air conditioning systems.

The research aims to develop models of heat exchange apparatuses in Simscape to optimize temperature regimes in residential buildings. Currently, in heat supply systems, one of the ways to address the task of saving thermal energy is the implementation of individual heat substations (IHS) with an automation system [1]. An important parameter required for determining the optimal temperature regime of a building is the indoor temperature. The control objective in heat supply systems is to maintain the indoor air temperature under the influence of disturbance factors (outdoor air temperature, etc.), as well as the temperature of water supplied to the hot water supply (HWS) system, within given constraints [2].

Various solutions are applied for temperature regime control, such as standard controllers with setpoints according to temperature schedules, systems with fuzzy logic, neural network algorithms, etc. The specific states and properties of substances requiring heat exchange have led to the emergence of a wide range of technical solutions. The classification of recuperators includes more than a dozen varieties. The main types most commonly encountered in engineering and everyday life are as follows: [3].

Tubular. This scheme appeared as one of the first and, in its simplest form, consists of two straight pipes, one running inside the other of larger diameter. Shell-and-tube. A development of the tubular scheme, where the internal circuit is formed not by one but by multiple tubes combined into a bundle.

The outer pipe serves as a protective shell. Plate. More modern equipment with higher efficiency, as well as minimal size and low weight. Such an apparatus consists of individual plates with a corrugated surface.

Plate-fin. A variation of the scheme where channels between plates are created not by stamping on the surface but by additional elements (fins) secured by welding. The main advantage of an IHS is the supply of hot water to consumers with minimal losses. It allows for adjusting the temperature in an individual building through specific individual settings.

The device can be located either in a separate technical structure or in basements. An IHS ensures the supply of heat and water to a specific premises, as well as the organization of ventilation for objects of various purposes: residential, industrial, and municipal. Heat substations serve both single buildings—small houses or structures—and a group or even a network of objects. In each case, a specific IHS scheme is selected, which includes: metering of heat and heat carrier consumption, protection of the heat consumption system from an emergency increase in the parameters of the network water, system shutdown, uniform distribution of the heat carrier, regulation and control of the circulating fluid parameters, conversion of the heat carrier type.

The IHS diagram is shown in Figure 1. Figure 1. IHS diagram [4]. A standard IHS (Individual Heat Substation) diagram includes: District heating supply inlet.

Metering device. Connection of the ventilation system. Connection of the heating system. Connection of the hot water supply system.

Pressure balancing between the heat consumption and heat supply systems. Make-up for heating and ventilation systems connected via an independent circuit. Each heat substation has its own connection diagram, which is selected based on the characteristics of the energy source. The IHS scheme can be dependent or independent.

In the first case, water enters the heating circuit directly from the external network, and the temperature is regulated by mixing it with return water. In an independent scheme, a double-circuit heat exchanger plays a key role. The heat transfer fluid from the boiler circuit enters the heat exchanger and transfers heat to a secondary circuit. Such an IHS scheme can be applied to all types of heat energy consumption, from heating to ventilation [5].

Shell-and-tube heat exchangers belong to the category of surface-type recuperative heat exchangers. The widespread use of these apparatuses is primarily due to their design reliability and a wide range of configurations for various operating conditions: Single-phase flows, boiling, and. Vertical and horizontal designs. A wide range of coolant pressures, from vacuum to 8.0 MPa.

Heat exchange surface areas ranging from small (1 m²) to very large (1000 m² and more). The possibility of using various materials according to requirements for cost, aggressiveness of media, temperature regimes, and coolant pressures. The use of various heat exchange surface profiles inside and outside the tubes, as well as various turbulators. The ability to extract the tube bundle for cleaning and repair.

The following types of shell-and-tube heat exchangers are distinguished: Heat exchangers with fixed tube sheets (rigid-tube heat exchangers). Heat exchangers with fixed tube sheets and a shell expansion joint. Heat exchangers with a floating head. Heat exchangers with U-tubes.

Shell-and-tube heat exchangers with fixed tube sheets are characterized by their simple design and, consequently, lower cost. A shell-and-tube heat exchanger consists of a bundle of heat exchange tubes located inside a cylindrical body (shell). One coolant flows inside the tubes, while the other flows over the external surface of the tubes. The tube ends are secured by rolling, welding, or brazing into the tube sheets.

Baffles are installed inside the shell using spacer tubes. The baffles support the tubes to prevent sagging and direct the coolant flow in the shell space, thus intensifying heat transfer. Nozzles for the inlet and outlet of the shell-side coolant are welded to the shell. In some cases, impingement plates are installed at the shell-side inlet to reduce tube bundle vibration, ensure uniform flow distribution in the shell space, and minimize erosion of the tubes closest to the inlet nozzle.

A channel cover (distribution chamber) and a rear cover with nozzles for the inlet and outlet of the tube-side fluid are attached to the shell via flanged connections. As part of the technical upgrade of oil treatment control systems, it is possible to install a packaged individual heat substation (PIHS) and a shell-and-tube heat exchanger (STHE). A variant of the shell-and-tube heat exchanger connection is shown in Figure 2. Figure 2.

Connection of a shell-and-tube heat exchanger at a process unit. The oil stream supplied to the Shell-and-Tube Heat Exchanger (STHE) enters from the bottom of the stabilization column to facilitate the heat exchange process. The heating system of the Oil Treatment Plant is based on the principle of heat exchange. For this purpose, heat transfer fluids are used, which circulate through the system and transfer heat from the source to the objects requiring heating.

Oil cooling is performed by an intermediate heat transfer fluid via a heat exchanger. The most commonly used heat transfer fluids for this purpose are water, steam, electricity, hot gases, and petroleum products. Steam is the most prevalent option, as it is non-flammable, offers good heat transfer properties, has low weight, and is easily transportable. Table 1.

Data on heat carriers of the shell-and-tube heat exchanger. Heating, Ventilation, and Air Conditioning (HVAC) (an abbreviation for Heating, Ventilation, & Air Conditioning) constitute a set of technologies aimed at maintaining specific air parameters—temperature, humidity, and chemical composition—inside enclosed spaces, including vehicle cabins (climate control). The development of ventilation and air conditioning systems is a crucial part of the engineering industry, based on the principles of thermodynamics, fluid dynamics, and heat transfer. HVAC systems play a key role in ensuring comfortable conditions in industrial and administrative buildings, swimming pools, and other structures, where maintaining optimal temperatures and humidity is achieved through the treatment of outdoor air.

They are also an integral part of modern «smart» homes. The primary goals of climate control (HVAC) management include: Creating and maintaining a comfortable indoor climate for people, plants, animals, or material assets within buildings or structures. Conserving energy required to create and maintain the desired climate. This can be applied in residential spaces, vehicle cabins, spacecraft, and other facilities.

Climate control is managed through various engineering systems, such as underfloor heating, chilled ceilings, radiators, fan coil units, air conditioning and ventilation systems, humidifiers and dehumidifiers, air ionizers, and others. To effectively manage all these devices, an integrated climate control system is necessary. When properly configured, the control system should ensure all components work harmoniously under any conditions, accounting for changes such as open or closed windows, the presence of people in the room, time of day, day of the week, and fluctuations in energy resource tariffs. Additionally, modern buildings can be equipped with remote climate control systems accessible via the internet, mobile applications, or dispatcher computers.

An example of a vehicle HVAC system is shown in Figure 3. The model was taken from the MatLab library. Figure 3. Model of a vehicle HVAC system.

This example simulates the flow of moist air in a vehicles Heating, Ventilation, and Air Conditioning (HVAC) system. The vehicle cabin air volume is considered as a space where moist air exchanges heat with the environment. The moist air passes through a recirculation flap, a fan, an evaporator, a mixing door, and a heater before returning to the cabin. The recirculation flap selects the flow source – either from the cabin or from the outside.

The mixing door valve directs the flow around the heater to regulate the temperature. The model can be run in two modes: using predefined system inputs or with manual data input. The parameters for controlling the HVAC in the predefined system inputs are located in the «System Inputs» subsystem. In the case of manual input, control parameters can be adjusted during operation using the controls on the dashboard.

The resulting output plots are shown in Figure 4. Figure 4. Temperature regime plots. Thus, to save thermal energy and improve the quality of transient processes when controlling a buildings thermal regime, the use of predictive models is proposed.

The Simscape library of the Matlab package, with its capability for linearizing the obtained models, is suitable for this purpose. An Individual Heat Substation (IHS) is a complex of modern units and equipment that enables the saving of heat carrier and the creation of an optimal microclimate inside buildings and premises. Operational costs following IHS installation can be substantially reduced, additionally, thermal energy losses are minimized, and overall heat carrier consumption is decreased.


Полная версия статьи PDF

Номер журнала «Вестник науки» № 5 (98) том 5


Ссылка для цитирования:

Batyrov A.R., Mingalev M.E. A VARIANT OF SIMULATION MODELING FOR A TECHNOLOGICAL OBJECT IN SIMULINK/SIMSCAPE // Журнал «Вестник науки» от 31 мая 2026 г. № 5 (98) том 5. С. 2037 - 2045. 2026 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/31211 (дата обращения: 29.11.2026 г.)


Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/31211



Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com


Вестник науки © 2026.    16+




* В выпусках журнала могут упоминаться организации (Meta, Facebook, Instagram) в отношении которых судом принято вступившее в законную силу решение о ликвидации или запрете деятельности по основаниям, предусмотренным Федеральным законом от 25 июля 2002 года № 114-ФЗ «О противодействии экстремистской деятельности» (далее - Федеральный закон «О противодействии экстремистской деятельности»), или об организации, включенной в опубликованный единый федеральный список организаций, в том числе иностранных и международных организаций, признанных в соответствии с законодательством Российской Федерации террористическими, без указания на то, что соответствующее общественное объединение или иная организация ликвидированы или их деятельность запрещена.