RESEARCH OF METHODS FOR SUPPRESSING REACTIVE INDUCTIVE ENERGY OF CONTROL WINDING OF ELECTRIC APPARATUS

Abstract: a severe switching mode for electrical devices occurs when the control winding circuit is disconnected from the DC voltage source. As a result, the reactive inductive energy accumulated in the control winding causes an overvoltage in the commutator key, which negatively impacts the contacts service life and, in the case of a semiconductor switch, can lead to a breakdown of the semiconductor element. Options for suppressing reactive inductive energy and their characteristics are known. The effect of resistor, semiconductor diode, and capacitor options connected in parallel with the control winding on overvoltage is studied, and the results, analysis, and corresponding conclusions of the study are presented. The effect of overvoltage on residual magnetic induction in the working gap of the magnetic circuit is also studied. The results of the study, analysis, and corresponding conclusions are presented.

Keywords: control winding, commutator switch, overvoltage, reactive inductive energy, residual induction.

https://doi.org/10.24412/2712-8849-2026-699-2835-2845

Introduction. Heavy switching conditions in electrical apparatus (EA) (electromagnetic, electromechanical) occur when the control winding (CW) circuit is disconnected from the DC voltage source. The reactive inductive energy accumulated in the CW causes overvoltage (OV) in the commutator key. If the electrical circuit is switched by electromechanical contacts, an electric spark or arc occurs in them, which negatively impacts the contact’s service. If an electrical circuit is switched by a semiconductor key, the OV can cause a breakdown of the semiconductor element. The OV can also negatively affect the semiconductor elements of the power supply. Professional literature provides detailed descriptions of various methods for quenching reactive inductive energy and their specific features. These methods quench inductive energy not by a commutator key, but by a circuit shunting of the CW, thereby eliminating negative effects. These methods are also used to modify the dynamic parameters of EA, particularly their time parameters [1-6]. Lifting electromagnets (LEs), powered by a DC voltage source, are known for their usage in lifting and moving ferromagnetic loads. After disconnecting the power source, a light load remains attached to the electromagnet due to the residual magnetization of the magnetic wire. Therefore, the design leaves a certain air gap between the load and the electromagnet pole. This design increases the size, weight, and power consumption of the LE. One solution is to apply a voltage of a certain magnitude of the opposite polarity to the CW after disconnecting the LE, which dampens the residual magnetic induction in the magnetic wire. This option is often used in practice, but it makes the LE control circuit more complex [7-9]. The purpose of the work. 1. Develop and prepare a research system within which the most common methods of reactive inductive energy suppression will be studied. 2. To research the residual magnetic induction in the working gap of the magnetic circuit of the EA, depending on the options for quenching the inductive reactive energy. Research tools and preparation. To conduct the study, a research system was developed, prepared and assembled, a photograph of which is shown in Fig. 1. The system includes: a LONGWEI-K3010D DC voltage source, a HAMEG-203-6 dual-beam oscilloscope (OS), Vici DM4070 and LINI-T digital multimeters, a Vici-VC480C+ milliohmmeter, a BST-600 teslameter, a TV1-2 (ТВ1-2), electromechanical switch, an RPU-4 (РПУ-4), electromagnetic relay, a D226B (Д226Б), semiconductor diode, a capacitor block of various capacities with the possibility of parallel connection of 0.001...5.41μF with a total capacity of up to 12.235μF 160V, other devices and auxiliary equipment. Fig. 1. Photograph of the research system. The choice of the EA RPU-4 electromagnetic relay for the study was determined by its ease of testing. Its CW parameters were: active resistance RCW=2.92kOhm and inductance LCW=9.2H. During the study, the relays operating gap was in an open, fixed state. The choice of the TV1-2 switch is due to the fact that mechanical contacts are disconnected without vibration and chatter of the contact parts, which does not exclude other types of switching contacts [10-12]. The research process and results. At the first stage, the overvoltage generated at the switching contacts of the electromechanical switch S was investigated in accordance with the electrical circuit shown in Fig. 2. Fig. 2. Electrical circuit commutation of the RPU-4 electromagnetic relay. After disconnecting the electrical circuit from the supply voltage at time t0, an OV occurs between the mechanical contacts of the TV1-2 switch due to the reactive inductive energy accumulated in the CW. The change in OV over time t is shown in Fig. 3, where Uc is the voltage drop across the closed contacts. Fig. 3. The nature of the intercontact overvoltage U at the moment of opening the electrical circuit depending on time t.The OV was measured using an oscilloscope. The power supply voltage of the EA was U=4V, and the measured OV UOV at the switch contacts was approximately UOV=130V. The choice of a low supply voltage value was determined by the possibility of measuring a large OV value. According to the well-known computational expression. UOV= ICW(LCW / Cc)1/2,where ICW is the current in the CW, Cc is the contact capacitance of the switch. The corresponding data were as follows: ICW=1.37mA, LCW=9.2H, Cc=1.5nF, and the calculated data was UOV=107,3V. With the same supply voltage, the OV study was carried out in the variants shown in Fig. 4. These are variants with a resistor R connected in parallel to the CW (a), a semiconductor diode VD (b) and a capacitor C (c). Fig. 4. Considered options for paying off the OV.To present and analyze the measurement results, the proportionality coefficient KOV=UOV/U was used, characterizing the superiority of the obtained OV over the supply voltage U. The results of the study for specific resistance values R are presented in Table 1. Table 1. Parallel resistance test results. Small values of parallel-connected resistances help reduce the amplitude of the overvoltage, but create additional power losses in the resistor R. When connecting the D226B diode in parallel, a KOV value of 3 was obtained, corresponding to approximately R=5kOhm. This result is due to the low Uсn value, at which the diode is partially open. With a high U value, the diodes internal dynamic resistance is approximately 35Ohms, eliminating the possibility of overvoltage. Some results from the study with capacitor C connected in parallel to the CW are presented in Table 2. Table 2. Test results for parallel-connected capacitors. The obtained results show that at large values of the capacitor capacitance, the reduction of OV occurs well, and there are practically no additional losses compared to the option of connecting a resistor, with the exception of the short-term charging process of C. The influence of parallel-connected elements on the magnitude of residual induction Bδ in the working gap of the magnetic circuit of an electromagnetic relay was investigated using a teslameter by placing a Hall sensor in the working gap of the relay. In the case of the U=100V winding of the research variant shown in Fig. 2, the value of magnetic induction Bδ in the working gap of the relay was approximately Bδ=274mT, and after disconnection from the supply voltage, the value of residual induction was Bδ=13mT. The current in the relay CW decreases stepwise, according to curve 1 shown in Fig. 5. Fig. 5. Current decline ICW in CW with respect t time.In the variants with small values of C, R and VD, the current in CW decreases in accordance with the 2 curves shown in Fig. 5, and no decrease in the value of Bδ is observed. Starting from a certain value of C, an oscillatory loop arises between C and CW, and the decrease in current in CW becomes an antiphase variable with a decaying amplitude. The measured Bδ values for specific C values are given in Table 3. Table 3. Values of residual induction in the working gap of a magnetic circuit with a parallel connection of a capacitor. According to the obtained results, the residual induction decreased by approximately 13 times, reaching about 1mT. In the case of the value C=1.01μF, the measured period of oscillation Tm of the oscillation circuit under study was approximately Tm=22ms, and the frequency was fm= 45,4Hz. According to expressions found in literature: T=2π1LCW − RCW2LCW2, f=1/TThe following data were obtained during calculations: Tc=21.8ms, fc=45.8Hz. The resonant frequency and oscillation period of the oscillatory circuit were, respectively: T0=2πLCWC =19,1∙10−3s, f0=1/T0=52,3Hz.Based on the results of the study, a range of values for parallel-connected capacitors was determined from which a value can be selected that minimizes residual magnetic induction. Using the known condition for the occurrence of oscillations in a parallel-connected LC circuit and making certain changes, the optimal value of the parallel-connected capacitor can be selected from the following limit: LCW/RCW2 < C< 4LCW/RCW2. (1)Sometimes a resistor R0 is connected in series with the capacitor C to limit the circuit current while the capacitor is charging, in which case R0 is added to RCW in (1). Conclusion: - The results of the OV study may be useful in selecting the optimal extinguishing method. - The effectiveness of the proposed capacitor connection scheme for suppressing residual magnetic induction in the electromagnet winding has been practically confirmed. It is also applicable to lifting electromagnets. - Expression (1) is applicable to determining the range of values of the capacitor capacitance in the LC oscillatory circuit for the purpose of demagnetizing the magnetic wire of the EA. Gratitude. This work was supported by the RA MESCS State Committee of Science, in the frames of the research project «Automated Systems and Modeling» research base laboratory.


Полная версия статьи PDF

Номер журнала «Вестник науки» № 6 (99) том 1


Ссылка для цитирования:

Hovhannisyan A.T. RESEARCH OF METHODS FOR SUPPRESSING REACTIVE INDUCTIVE ENERGY OF CONTROL WINDING OF ELECTRIC APPARATUS // Журнал «Вестник науки» от 7 июня 2026 г. № 6 (99) том 1. С. 2835 - 2845. 2026 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/31635 (дата обращения: 29.11.2026 г.)


Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/31635



Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?
- напишите письмо в редакцию журнала: zhurnal@vestnik-nauki.com


Вестник науки © 2026.    16+




* В выпусках журнала могут упоминаться организации (Meta, Facebook, Instagram) в отношении которых судом принято вступившее в законную силу решение о ликвидации или запрете деятельности по основаниям, предусмотренным Федеральным законом от 25 июля 2002 года № 114-ФЗ «О противодействии экстремистской деятельности» (далее - Федеральный закон «О противодействии экстремистской деятельности»), или об организации, включенной в опубликованный единый федеральный список организаций, в том числе иностранных и международных организаций, признанных в соответствии с законодательством Российской Федерации террористическими, без указания на то, что соответствующее общественное объединение или иная организация ликвидированы или их деятельность запрещена.