INVESTIGATION INTO METHODS FOR IMPROVING THE ENERGY EFFICIENCY OF BUILDING ENVELOPES IN PUBLIC BUILDINGS
Abstract: the article investigates methods for improving the energy efficiency of building envelopes in public buildings under the climatic conditions of Kazakhstan. Particular attention is paid to heat losses through external walls, roofs, floors and translucent structures. Modern thermal insulation materials and construction solutions, including multilayer walls, ventilated façades, external thermal insulation composite systems (ETICS) and energy-efficient glazing, are examined. The study employs analytical calculations of thermal resistance and a comparative assessment of the thermal properties of different insulation materials and building envelope systems. The findings highlight the importance of improving thermal insulation, eliminating thermal bridges and ensuring the airtightness of building envelopes. Practical recommendations are proposed for the design and energy renovation of public buildings in cold climatic regions.
Keywords: energy efficiency, building envelopes, public buildings, thermal insulation, thermal resistance, ventilated façades, energy-efficient glazing, heat losses, Kazakhstan.
https://doi.org/10.68367/33716
УДК 699.86
Saginbayev S.E.
first-year Master's student
Educational Programme 7M07302 — Construction,
Faculty of Architecture and Civil Engineering
Karaganda Technical University named after Abylkas Saginov
(Karaganda, Kazakhstan)
Baideldinova G.M.
PhD, Assistant Professor
Faculty of Mechanical Engineering
Department of Foreign Languages
Karaganda Technical University named after Abylkas Saginov
(Karaganda, Kazakhstan)
INVESTIGATION INTO METHODS FOR IMPROVING
THE ENERGY EFFICIENCY OF BUILDING
ENVELOPES IN PUBLIC BUILDINGS
Abstract: the article investigates methods for improving the energy efficiency of building envelopes in public buildings under the climatic conditions of Kazakhstan. Particular attention is paid to heat losses through external walls, roofs, floors and translucent structures. Modern thermal insulation materials and construction solutions, including multilayer walls, ventilated façades, external thermal insulation composite systems (ETICS) and energy-efficient glazing, are examined. The study employs analytical calculations of thermal resistance and a comparative assessment of the thermal properties of different insulation materials and building envelope systems. The findings highlight the importance of improving thermal insulation, eliminating thermal bridges and ensuring the airtightness of building envelopes. Practical recommendations are proposed for the design and energy renovation of public buildings in cold climatic regions.
Keywords: energy efficiency, building envelopes, public buildings, thermal insulation, thermal resistance, ventilated façades, energy-efficient glazing, heat losses, Kazakhstan.
In the context of rising energy costs and the growing need to reduce the carbon footprint of the construction sector, improving the energy efficiency of buildings has become a key priority. Public buildings, including administrative, educational, healthcare, cultural, and sports facilities, are characterized by extended operating hours, high occupancy rates, and substantial energy consumption for heating and cooling. In the sharply continental climate of Kazakhstan, where the heating season lasts more than six months and winter temperatures regularly drop below –25 to –30 °C, heat losses through the building envelope can account for 50–70% of the building's total heat losses [3].
Enclosing structures — external walls, roofs, floors on the ground or above unheated spaces, and translucent elements (windows, stained-glass systems, entrance groups) — form the main barrier between the internal microclimate and the external environment. Their thermal performance largely determines the energy consumption of the heating system, the level of thermal comfort of users and the risk of moisture condensation and mold formation.
The aim of this study is to investigate strategies for improving the energy efficiency of building envelope components in public buildings under the climatic conditions of Central Kazakhstan, particularly in the Karaganda region. The study also aims to compare the thermal performance of traditional and modern building envelope solutions and to develop practical recommendations for the design of new buildings and the energy-efficient renovation of existing facilities.
An analysis of the existing public building stock in Kazakhstan indicates that a significant proportion of buildings constructed during the second half of the twentieth century have inadequate thermal resistance of their building envelopes [3]. Typical brick and prefabricated panel walls dating from this period have thermal resistance values (R-values) ranging from 0.8 to 1.2 m²·°C/W, whereas current regulatory requirements, including SP RK 2.04-107-2022 [2], specify substantially higher values for regions with cold climatic conditions. The use of conventional double-glazed windows further contributes to increased heat losses.
Heat losses through the building envelope include transmission losses through opaque elements (walls, roof, floor), transmission losses through translucent structures, and infiltration of air through joints and defects. In cold climates the dominant share belongs to opaque walls and roofs, followed by windows. Thermal bridges at junctions of walls and slabs, around openings and at balcony slabs can significantly reduce the effective thermal resistance of the assembly. The research is based on analytical calculation of the thermal resistance of multilayer enclosing structures according to the standard methodology (ISO 6946) [1], comparison of the thermal conductivity coefficients of modern insulation materials, and analysis of constructive solutions used in energy-efficient construction. Climatic data for the Karaganda region are taken into account.
The reduced thermal resistance of a multilayer structure is calculated by the formula [1]:
R₀ = 1/αᵢ + Σ(δᵢ / λᵢ) + 1/αₑ.
where αᵢ and αₑ are the heat transfer coefficients of the internal and external surfaces, δᵢ is the thickness of the i-th layer, and λᵢ is its thermal conductivity coefficient.
Table 1. Presents typical values of thermal conductivity for insulation materials
commonly used in Kazakhstan.
Table 1. Thermal conductivity of selected insulation materials.
| Material | λ, W/(m·°C) | Density, kg/m³ |
Typical thickness, mm |
| Mineral wool (slabs) | 0.035–0.040 | 30–100 | 100–200 |
| Expanded polystyrene (EPS) | 0.035–0.042 | 15–35 | 100–150 |
| Extruded polystyrene (XPS) | 0.029–0.035 | 30–45 | 50–150 |
| Polyisocyanurate (PIR) | 0.022–0.028 | 30–50 | 50–120 |
| Aerated concrete (D400–D500) |
0.10–0.14 | 400–500 | 300–400 |
Calculations for typical wall assemblies show that the application of an additional external insulation layer of 100–150 mm of mineral wool or expanded polystyrene (λ ≈ 0.035–0.040 W/(m·°C)) increases the thermal resistance of a traditional brick wall from approximately 1.0 m²·°C/W to 3.5–4.5 m²·°C/W. This corresponds to a reduction of transmission heat losses through the wall by a factor of 3.5–4.5. When PIR boards (λ ≈ 0.022–0.028 W/(m·°C)) are used, the same thermal resistance can be achieved with a smaller thickness of the insulation layer.
Ventilated façade systems with an air gap and external cladding provide high thermal resistance and effective removal of moisture from the insulation layer, which is important for the continental climate. External thermal insulation composite systems (ETICS) remain a cost-effective solution for the modernization of existing public buildings. Roof structures also require attention: modern rigid insulation boards (PIR, XPS or high-density mineral wool) with a thickness of 150–200 mm allow reaching R-values of 4.0–6.0 m²·°C/W and higher.
For windows and stained-glass systems of public buildings it is recommended to apply units with R ≥ 0.8 m²·°C/W (preferably ≥ 1.0 m²·°C/W in the coldest regions) [5]. Triple-glazed units with low-emissivity coatings and inert gas filling represent the practical optimum. Reduction of the window-to-wall ratio to reasonable values, use of shading devices and careful sealing of installation joints contribute to further energy savings.
Particular attention should be paid to thermal bridges. Linear thermal bridges can reduce the overall energy performance of the envelope by 10–25% or more if they are not properly treated. The use of thermal break elements and continuous insulation layers is an integral part of any energy-efficient design. An integrated approach that simultaneously improves the thermal performance of walls, roof, floors and translucent elements, eliminates thermal bridges and provides controlled ventilation with heat recovery yields the greatest effect. Comprehensive energy renovation of the envelope can reduce heating energy consumption by 30–60% depending on the initial condition of the building [3].
The investigation confirms that the energy efficiency of public buildings in the climatic conditions of Kazakhstan can be substantially increased by improving the thermal performance of enclosing structures [4, 6]. The most effective measures include:
1. Application of modern thermal insulation materials with low thermal conductivity (mineral wool, EPS, XPS, PIR) in multilayer wall and roof assemblies.
2. Use of ventilated façade systems or ETICS for both new construction and retrofit of existing buildings.
3. Installation of energy-efficient translucent structures with R ≥ 0.8–1.0 m²·°C/W.
4. Elimination of thermal bridges and improvement of airtightness of the envelope.
5. Integrated design approach that considers the interaction of all envelope components and the heating and ventilation systems.
The findings of this study can be used by designers, energy auditors, and municipal authorities in the development of projects for new public buildings and energy modernization programs targeting the existing building stock. Further research should focus on detailed numerical modeling of specific types of public buildings, as well as on life-cycle cost analyses of various building envelope solutions, taking into account local economic conditions.
REFERENCES:
1. ISO 6946:2017. Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods. Geneva: International Organization for Standardization, 2017 https://doi.org/10.3403/30313347.
2. SP RK 2.04-107-2022. Thermal protection of buildings. Astana: Committee for Construction and Housing and Communal Services, 2022.
3. Adilova D., Tukhtamisheva A. et al. Heat loss assessment and energy renovation strategies for Soviet-era buildings in cold climates of Kazakhstan // Energy and Environment. 2026.
4. Gorshkov A.S., Vatin N.I. Energy efficiency of enclosing structures // Magazine of Civil Engineering. 2013. No. 8. Pp. 5–14.
5. Study of the possibility of transition to more stringent energy efficiency requirements for translucent structures in the Republic of Kazakhstan // Buildings. 2025. Vol. 15. No. 13 https://doi.org/10.3390/buildings15132354.
6. An exhaustive search energy optimization method for residential building envelope in different climatic zones of Kazakhstan // Buildings. 2021. Vol. 11. No. 12 https://doi.org/10.3390/buildings11120633.
Полная версия статьи PDF
Номер журнала «Вестник науки» № 11 (104) том 1
Ссылка для цитирования:
INVESTIGATION INTO METHODS FOR IMPROVING THE ENERGY EFFICIENCY OF BUILDING ENVELOPES IN PUBLIC BUILDINGS // Журнал «Вестник науки» от 1 ноября 2026 г. № 11 (104) том 1. С. 907 - 912. 2026 г. ISSN 2712-8849 // Электронный ресурс: https://www.вестник-науки.рф/article/33716 (дата обращения: 15.11.2026 г.)
Альтернативная ссылка латинскими символами: vestnik-nauki.com/article/33716
Нашли грубую ошибку (плагиат, фальсифицированные данные или иные нарушения научно-издательской этики) ?